<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-13 15-24-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 54 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 72 kHz 17892 5,3543
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,1 dBr 4,14 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 72 kHz MIN: 10 kHz % above 76 kHz: 5,3543 Acquired: 2025/11/13 15.23.19 Total samples: 17892 Equivalent time: 0:14:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,1 dBr MIN: 2,1 dBr AVE: 4,14 dBr % above 12,2 dBr: 0,0 Last value: 3,7 dBr (2025/11/13 15.23.19) 15.10 15.12 15.14 15.16 15.18 15.20 15.22 0 2 4 6 Pm [dBr]